34 research outputs found

    Transcatheter Repair and Replacement Technologies for Mitral Regurgitation:a European Perspective

    Get PDF
    PURPOSE OF REVIEW: We aimed to picture the contemporary landscape of available catheter-based repair and replacement solutions for mitral regurgitation (MR) in Europe. RECENT FINDINGS: Edge-to-edge repair remains the dominant technique for transcatheter mitral valve repair especially in the context of secondary mitral regurgitation. Two recent randomized trials reported seemingly contradicting clinical results with transcatheter edge-to-edge repair for patients with heart failure and severe secondary MR. A proportionality framework related to secondary MR was proposed to help explain inconsistencies but requires further research. (In)Direct annuloplasty primarily aims to correct secondary MR; however, the scientific basis seems less robust. One dedicated transcatheter heart valve has the CE mark for mitral valve replacement but requires transapical access. Balloon-expandable transcatheter aortic valve platforms are emerging for transvenous transseptal mitral replacement in the context of mitral annular calcification, a failing surgical mitral bioprosthesis, or annuloplasty. Advanced computed tomography imaging techniques improved pre-procedural planning and introduced the option for modeling and simulation. SUMMARY: Development of a toolbox of catheter-based technologies, complementary imaging modalities, and refined patient selection offer novel perspectives to high-risk patients with primary or secondary MR. Clinical trials are required to help formulate evidence-based guidelines for the management of mitral valve disease

    Sex-specific aortic valve calcifications in patients undergoing transcatheter aortic valve implantation

    Get PDF
    To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th–75th percentile 77.5–85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th–75th percentile 76.5–84.5) vs. 82.4 (78.2–85.9), P ≤ 0.01] and had a larger annulus area [512 mm 2 (25th–75th percentile 463–570) vs. 405 mm 2 (365–454), P < 0.01] and higher Agatston score [2567 (25th–75th percentile 1657–3913) vs. 1615 (25th–75th percentile 905–2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women

    Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: The INTERSECT registry.

    Get PDF
    BACKGROUND New permanent pacemaker implantation (new-PPI) remains a compelling issue after Transcatheter Aortic Valve Replacement (TAVR). Previous studies reported the relationship between a short MS length and the new-PPI post-TAVR with a self-expanding THV. However, this relationship has not been investigated in different currently available THV. Therefore, the aim of this study was to investigate the association between membranous septum (MS)-length and new-PPI after TAVR with different Transcatheter Heart Valve (THV)-platforms. METHODS We included patients with a successful TAVR-procedure and an analyzable pre-procedural multi-slice computed tomography. MS-length was measured using a standardized methodology. The primary endpoint was the need for new-PPI within 30 days after TAVR. RESULTS In total, 1811 patients were enrolled (median age 81.9 years [IQR 77.2-85.4], 54% male). PPI was required in 275 patients (15.2%) and included respectively 14.2%, 20.7% and 6.3% for Sapien3, Evolut and ACURATE-THV(p ​< ​0.01). Median MS-length was significantly shorter in patients with a new-PPI (3.7 ​mm [IQR 2.2-5.1] vs. 4.1 ​mm [IQR 2.8-6.0], p ​= ​<0.01). Shorter MS-length was a predictor for PPI in patients receiving a Sapien3 (OR 0.87 [95% CI 0.79-0.96], p ​= ​<0.01) and an Evolut-THV (OR 0.91 [95% CI 0.84-0.98], p ​= ​0.03), but not for an ACURATE-THV (OR 0.99 [95% CI 0.79-1.21], p ​= ​0.91). By multivariable analysis, first-degree atrioventricular-block (OR 2.01 [95% CI 1.35-3.00], p = <0.01), right bundle branch block (OR 8.33 [95% CI 5.21-13.33], p = <0.01), short MS-length (OR 0.89 [95% CI 0.83-0.97], p ​< ​0.01), annulus area (OR 1.003 [95% CI 1.001-1.005], p ​= ​0.04), NCC implantation depth (OR 1.13 [95% CI 1.07-1.19] and use of Evolut-THV(OR 1.54 [95% CI 1.03-2.27], p ​= ​0.04) were associated with new-PPI. CONCLUSION MS length was an independent predictor for PPI across different THV platforms, except for the ACURATE-THV. Based on our study observations within the total cohort, we identified 3 risk groups by MS length: MS length ≤3 ​mm defined a high-risk group for PPI (>20%), MS length 3-7 ​mm intermediate risk for PPI (10-20%) and MS length > 7 ​mm defined a low risk for PPI (<10%). Anatomy-tailored-THV-selection may mitigate the need for new-PPI in patients undergoing TAVR

    Computed Tomography-Derived 3D Modeling to Guide Sizing and Planning of Transcatheter Mitral Valve Interventions

    Get PDF
    A plethora of catheter-based strategies have been developed to treat mitral valve disease. Evolving 3-dimensional (3D) multidetector computed tomography (MDCT) technology can accurately reconstruct the mitral valve by means of 3-dimensional computational modeling (3DCM) to allow virtual implantation of catheter-based devices. 3D printing complements computational modeling and offers implanting physician teams the opportunity to evaluate devices in life-size replicas of patient-specific cardiac anatomy. MDCT-derived 3D computational and 3D-printed modeling provides unprecedented insights to facilitate hands-on procedural planning, device training, and retrospective procedural evaluation. This overview summarizes current concepts and provides insight into the application of MDCT-derived 3DCM and 3D printing for the planning of transcatheter mitral valve replacement and closure of paravalvular leaks. Additionally, future directions in the development of 3DCM will be discussed

    Vascular complications with a plug-based vascular closure device after transcatheter aortic valve replacement: Predictors and bail-outs

    Get PDF
    Background: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking. Aim: To evaluate MANTA in a real-world population and identify predictors for vascular complications. Methods: All patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) between January 2016 and May 2020 with MANTA closure were included. Baseline characteristics were collected, pre-procedural computed tomography and post-deployment femoral angiograms were analyzed for anatomical differences. The primary endpoint was a composite of access site related major and minor vascular complications at 30 days follow-up according to the VARC-2 definitions. Secondary endpoints included bleeding, time to hemostasis, procedural length and incomplete arteriotomy closure or arterial occlusion by angiography. A Cox proportional hazards model was used to compare all-cause mortality for patients with and without an access site complication. Results: The 512 patients underwent TAVR with MANTA access closure. Median age was 80 (IQR 75–85), 53% was male, median BMI was 26.4 kg/m2 (IQR 23.4–29.7). Access site related major- or minor vascular complication occurred in 20 (4%) and 23 (4%) of patients respectively. Median time to hemostasis was 42 s (IQR 28–98). Post deployment angiogram showed an occlusion in 24 patients (5%), incomplete closure in 60 patients (12%) or both in three patients (1%). Of these 87 patients, 36 (41%) had a vascular complication. Femoral artery diameter (OR 0.70 [0.53–0.93]), low- (OR 3.47 [1.21–10.00]) and high (OR 2.43 [1.16–5.10]) arteriotomies were independent predictors for vascular complications. Conclusion: In this contemporary TAVR population, access-site related complications occurred in 8% of patients and were mainly due to percutaneous closure device failure. Small artery diameter and off-target punctures were independent predictors

    Simplified trans-axillary aortic valve replacement under local anesthesia – A single center early experience

    Get PDF
    Background: The axillary artery is an alternative route for patients with comorbidities and unfavorable femoral arteries who need transcatheter aortic valve replacement (TAVR). Simplified trans-axillary transcatheter aortic valve replacement (TAx-TAVR) implies a completely percutaneous approach under local anesthesia and arteriotomy closure with vascular closure techniques. Herein, we report on early experience with simplified TAx-TAVR under local anesthesia. Methods: We enrolled all consecutive patients who underwent simplified TAx-TAVR in our center. Main study parameter was the incidence of axillary access related major vascular complications within 30 days. Secondary parameters included a composite early safety endpoint, axillary access-site related vascular/bleeding complications and short-term mortality. Post TAVR axillary stent patency was evaluated during follow-up by CT-analysis. Results: Between July 2018 and April 2020, Tax-TAVR was attempted in 35 patients with a mean age of 79 years. Local anesthesia and conscious sedation were used in 91.4% (n = 32) and 8.6% (n = 3) respectively. A covered stent was needed for complete axillary hemostasis in 44.1% (n = 15). Device success was achieved in 91.2% (n = 31/34). The 30-day axillary artery major vascular and ≥major bleeding complication rates were 14% (n = 5) and 11% (n = 4). The early safety endpoint was reached in 22.9% (n = 8). Mortality rates at 30 days and six months were 2.9% and 11.6%. Computed tomography (CT) confirmed axillary stent patency during follow-up in 82% (n = 9/11). Conclusions: In patients with high/prohibitive surgical risk and unsuitable femoral access, simplified TAx-TAVR under local anesthesia offers a valuable alternative for transfemoral TAVR but requires advanced access site management techniques including covered stents. Our data suggest an unmet clinical need for dedicated TAx closure devices

    Impact of baseline and newly acquired conduction disorders on need for permanent pacemakers with 3 consecutive generations of self-expanding transcatheter aortic heart valves

    Get PDF
    Introductions: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)). Methods: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation. We performed multivariable regression analysis to estimate the effect of the three separate transcatheter heart valves (THV's) on need for PPI at 30 days. Results: TAVR was performed with CoreValve (N = 113), Evolut R (N = 157) or Evolut PRO (N = 92). Conduction dynamics were similar between the different THVs. Overall, Evolut R and PRO showed a tendency towards less PPI compared to CoreValve (17% vs. 19% vs. 27%, P = 0.08), which was driven by a lower PPI rate in Cohort A (6% vs. 11% vs. 25%, P = 0.002). Need for PPI was restricted to patients with persistent QRS-prolongation in Cohort A (26/106) but did not correlate with conduction dynamics in Cohort B. In multivariable logistic regression analysis the use of Evolut R (OR 0.38, 95% CI 0.19–0.78, P = 0.008) and PRO (OR 0.41, 95% CI 0.19–0.91, P-value = 0.028) were independently associated with less need for PPI. Conclusion: The newer generations Evolut R and PRO were associated with less PPI compared to CoreValve. Acquired persistent conduction abnormalities predicted PPI after TAVR only in patients with normal conduction at baseline. Our findings may help identify eligible patients for early discharge after Evolut R/PRO TAVR
    corecore